| The
Features You Want - Included at No Extra Charge...
High/Low Temperature
Limit Controller and Alarm Viewing Window Two 4"
Access Ports Adjustable Shelf Casters Built-In Refrigeration
Gauges
|
|
| TECHNICAL
FEATURES
The window is constructed of 6 panes of tempered glass separated by low-conductivity spacers to keep thermal losses to a minimum. Our unique design virtually eliminates exterior window sweating during normal temperature cycling conditions. The stainless-steel interior liner is heliarc welded, while the refrigeration compartment behind the liner is double-insulated and carefully sealed. These design features reduce thermal losses and prevent moisture migration, ensuring years of optimum performance while keeping the cabinet rust-free. Reliability
& Safety Thats Designed In All electrical control components are UL approved. Each branch circuit is individually fused. A main power disconnect switch is provided on the front panel. The nichrome air-heater has a low watt-density and even heat distribution for reliable performance and fast response. A fusible link provides fail-safe protection against thermal runaways, in addition to the microprocessor-based high/low limit controller. The side and rear panels are removable to permit complete access to the refrigeration system for ease of service and preventive maintenance. Shown above with the optional circular chart recorder, which mounts conveniently in the front. |
|
| Should
I buy a TestEquity 1007S Single-Stage or 1007C
Cascade Chamber?
TestEquity Single-stage refrigeration systems are capable of achieving workspace temperatures down to -35°C. This is fine for many commercial and industrial tests that require low temperatures of typically 0°C, -10°C or -25°C. A single-stage system uses one compressor to directly cool the workspace. Single-stage systems offer these benefits over similarly-sized cascade systems:
TestEquity Cascade refrigeration systems are capable of achieving workspace temperatures down to -75°C. This is required for many ruggedized industrial, automotive and military tests that require low temperatures of typically -40°C, -55°C or -65°C. A cascade system uses two interdependent compressors. One compressor (low-stage) directly cools the workspace. The other compressor (high-stage) cools a heat-exchanger (cascade condenser) to remove heat from the low-stage. If you need to go below -35°C, choose the TestEquity 1007C. |