Return to Home Page

  Environmental Chambers  

   TestEquity Model 1007H Temperature/Humidity Chamber


Products

Why Buy a
TestEquity
Chamber

About
TestEquity

Contact Us

Home

Specifications  Download the Manual  Prices

TestEquity 1007H Temp/Humidity Chamber
  • Temperature -73°C to +175°C
  • Humidity 10% to 95% RH
  • 7 Cu Ft Workspace (24 W x 21 H x 24 D)
  • Programmable Temperature Controller
  • RS-232 Interface, Optional GPIB & Ethernet
  • LabVIEW Drivers
  • High/Low Limit Control and Alarm
  • Viewing Window & Interior Light
  • 4" Access Ports on Left & Right Side
  • Non-CFC Cascade Refrigeration
  • 3 Year Parts, 1 Year Labor Warranty
  • Fast Delivery From Stock
  • Available For Sale, Rental or Lease
The Features You Want - Included at No Extra Charge...

Programmable Controller

Programmable Temperature/Humidity Controller
Up to 256 steps can be programmed into as many as 40 nameable profiles. The context sensitive information key and guided steps make profile programming fast and easy. A four-line backlit LCD displays programming, setup, operating and help information. A large LED readout indicates the actual chamber temperature with 0.1° resolution. Internal logic provides refrigeration compressor control for responsive and reliable performance. Includes seven event outputs to control remote devices. RS-232 communications is also included. GPIB, Ethernet and analog retransmit are available as options.
More about the Temperature Controller
>>
RS-232 Programming Resources and LabVIEW drivers >>
GPIB Programming Resources and LabVIEW drivers >>
Ethernet Inteface information >>

High/Low Temperature Limit Controller and Alarm
Provides independent protection against excess temperatures. Both high and low limits can be set. The upper LED readout indicates the actual chamber temperature while the lower readout indicates the status The limit controller will shut down the chamber and trigger the audible alarm in the event of an out of limit condition. A set of uncommitted contacts are available to provide a safety power interlock for your test sample.

Accurate Humidity Measurement
A fast responding capacitive-type sensor eliminates the need for unreliable wet-wicks.

Viewing Window
Heated multi-pane window eliminates fog and condensation without a manual wiper.

Two 4" Access Ports
Lets you attach wires and sensors to your test sample through both the left and right side of the chamber.

Adjustable Shelf
A heavy-duty stainless steel wire shelf ensures proper airflow around your test sample for uniform temperature distribution.

Built-In Refrigeration Gauges
Provides system status for easy preventive maintenance and service.

Casters
Rugged 3" casters permit easy movement.

World's Best Chamber WarrantyWorld’s Best Chamber Warranty
Only TestEquity offers a 3-year warranty on parts and 1-year warranty on labor at your domestic site. Our nationwide service network is qualified to do the job right. And we always have replacement parts in stock for immediate shipment.

TECHNICAL FEATURES

Accurate Humidity Measurement
A fast responding capacitive-type sensor eliminates the need for unreliable wet-wicks.

Reliable Vapor Generator
The stainless-steel assembly is fully protected against low-water and over-temperature conditions. Unlike "atomizing" systems, the heated vapor generator has no pump to fail or orifice to clog.

Heated Viewing Widow
Eliminates fog and condensation without a manual wiper.

Water Recirculation System
The optional water recirculation system provides a reliable source of demineralized water for the humidity system, using ordinary tap or pre-filtered water. Condensate from the chamber is returned back to the water tank. The recirculation pump operates only when needed to fill the chamber's humidifier to the correct level. Perfect for installations where a water line and drain are not available.
(Optional, and highly recommended)

Reliability & Safety That’s Designed In
Non-CFC refrigerants are used in a cascade (two compressors) configuration. Expansion valves provide optimum performance throughout the operating range. Pressure regulators keep the operating pressures within safe limits regardless of load conditions. Liquid injection ensures cool compressor operation during high-temperature pull down for long life. Sequential starting of each compressor reduces the current demand on start-up. Each compressor is protected by high/low pressure switches. Care has been taken to use a minimum number of fittings, joints and welds to reduce the possibility of refrigerant leaks.

All electrical control components are UL approved. Each branch circuit is individually fused. A main power disconnect switch is provided on the front panel. The nichrome air-heater has a low watt-density and even heat distribution for reliable performance and fast response. A fusible link provides fail-safe protection against thermal runaways, in addition to the microprocessor-based high/low limit controller.

The side and rear panels are removable to permit complete access to the refrigeration and humidity system for ease of service and preventive maintenance.